SymbolDescriptionUse / Meaning
AAnalog SignalRepresents a continuous signal such as 4–20 mA
ACAnalysis ControllerControls analyzer-related parameters
AAHAnalysis Alarm (High)Alarm activates when analysis value exceeds high limit
AAHLAnalysis Alarm (High/Low)Alarm for both high and low abnormal analysis values
AALAnalysis Alarm (Low)Alarm when analysis value drops below low limit
ASAir SupplyIndicates pneumatic air supply
ASDHAnalysis Shutdown (High)Shutdown triggered at high analysis value
ASDLAnalysis Shutdown (Low)Shutdown triggered at low analysis value
ASHAnalysis Switch (High)Switch activates at high analysis value
ASHLAnalysis Switch (High/Low)Switch for both high and low conditions
ASLAnalysis Switch (Low)Switch activates at low analysis value
ATAnalysis TransmitterMeasures and transmits analyzer signals
BCBurner ControllerControls burner operation
BAHBurner Alarm (High)Alarm for high burner parameter
BAHLBurner Alarm (High/Low)Burner alarm for high and low limits
BALBurner Alarm (Low)Alarm for low burner parameter
BDVBlowdown ValveUsed for depressurizing or draining lines
BPRBack Pressure RegulatorMaintains upstream pressure
BSBurner SwitchManual or automatic burner switching
BSHBurner Switch (High)Switch activates at high condition
BSHLBurner Switch (High/Low)Burner switching for high/low limits
BSLBurner Switch (Low)Switch activates at low condition
BS&WBasic Sediment and WaterIndicates impurities in oil
CCPCentral Control PanelMain control and monitoring panel
CDSCompressor ShutdownShuts down compressor during fault
CFACommon Fault AlarmIndicates general system fault
CORCorrosimeterMeasures corrosion rate
CSCCar Seal CloseValve locked in closed position
CSOCar Seal OpenValve locked in open position
CVControl ValveRegulates process variable
E/IEMF to Current ConverterConverts voltage to current signal
ESElectrical SwitchElectrical switching device
ESDEmergency Shutdown StationManual emergency shutdown
ESDVEmergency Shutdown ValveValve closes during emergency
FALFlow Alarm (Low)Alarm for low flow condition
FAHFlow Alarm (High)Alarm for high flow condition
FCFlow Controller / Fail CloseControls flow or valve closes on failure
FCVFlow Control ValveControls flow rate
FEFlow ElementPrimary flow-sensing device
FIFlow IndicatorDisplays flow value
FICFlow Indicator ControllerIndicates and controls flow
FITFlow Indicator TransmitterIndicates and transmits flow
FOFail OpenValve opens on failure
FSFlow SwitchDetects flow presence
FTFlow TransmitterMeasures and transmits flow
GSInstrument Gas SupplyGas supply for instruments
HHydraulicIndicates hydraulic system
HOAHand/Off/Auto SwitchMode selection switch
HSHand SwitchManual switching
ICurrent SignalElectrical current signal
I/PCurrent to PneumaticConverts current to air pressure
LALevel AlarmAlarm for abnormal level
LCLevel ControllerControls liquid level
LCVLevel Control ValveRegulates level
LGLevel GaugeVisual level indication
LILevel IndicatorIndicates level
LITLevel Indicator TransmitterMeasures and transmits level
LSLevel SwitchSwitch based on level
MCCMotor Control CenterControls electric motors
NCNormally ClosedContact closed in normal state
NONormally OpenContact open in normal state
PAHPressure Alarm (High)Alarm for high pressure
PCPressure ControllerControls pressure
PCVPressure Control ValveRegulates pressure
PGPressure GaugeIndicates pressure locally
PIPressure IndicatorDisplays pressure
PITPressure Indicator TransmitterMeasures and transmits pressure
PSVPressure Safety ValveProtects against overpressure
PTPressure TransmitterMeasures and transmits pressure
RTDResistance Temperature DetectorMeasures temperature
RTURemote Terminal UnitRemote data acquisition
TCTemperature ControllerControls temperature
TITemperature IndicatorDisplays temperature
TITTemperature Indicator TransmitterMeasures and transmits temperature
TTTemperature TransmitterTransmits temperature signal
TWThermowellProtects temperature sensor
VAHVibration Alarm (High)Alarm for excessive vibration
VSHVibration Switch (High)Switch activates on high vibration
WSWater SupplyWater utility line
ZCPosition Switch (Closed)Indicates valve closed
ZOPosition Switch (Open)Indicates valve open